FluidPrep

Related Products

CP Select™ Concentrating Pipette

Experience the efficiency of the FluidPrep™ Concentrating Pipette System by InnovaPrep, engineered to simplify workflows and boost assay sensitivity. This system is highly effective in recovering microorganisms and particles, including bacteria, parasites, molds, fungal spores, whole cells, viruses, and synthetic particles, from sample volumes between 0.5 mL and 5 L.

The one-pass method uses robust filtration followed by instant sample recovery using InnovaPrep's patented Wet Foam Elution™ process delivering a highly concentrated sample ideal for detection by culture, PCR, sequencing, and more – with unprecedented speed and efficiency. For applications needing rapid, reliable sample concentration, this system provides a faster, simpler alternative to traditional culture enrichment, centrifugation, and ultracentrifugation methods.

Includes: 

  • CP Select Instrument
  • Accessory Kit  -  Includes the Storage Fluid Adapter, Permeate Line, Maintenance Tip
  • One-year manufacturer warranty

Consumable supplies (pictured) and optional accessories sold separately.

View Product

FluidPrep™ CPT - Irradiated

Single-Use, Irradiated Concentrating Pipette Tips (CPTs) are available in a variety of formats. Selecting the ideal CPT for use with the FluidPrep™ Concentrating Pipette System is crucial to achieving optimal performance - both in terms of speed and concentration factor of your target. 

 

Selecting the Right CPT - Factors to consider

1 - Pore Size based on Nature and Size of Target Particle

CPTs are available in four pore sizes – Ultra, 0.05 µm, 0.2 µm, and 0.45 µm to accommodate the wide range of target particle types and sizes. 

*Volume and flow rates will vary by matrix and selected menu settings

2 - Surface Area by Sample Matrix and Sample Volume

The complexity of your sample and overall volume to be processed will influence the speed and overall volume that can be processed effectively. Two options are available.

  • Standard CPTs Membrane surface area is 98 cm² nominal. Recommended for sample volumes over 200 mL and/or more complex or turbid matrices.
  • Mini 25 CPTs  - The membrane surface area is 25 cm² nominal and capable of smaller elution volumes with optimized menu settings. Recommended for sample volumes 200 mL or less and of low complexity/turbidity. Short-walled sample containers and the CP Sample Carousel are required for use.

As a general Rule of Thumb, we recommend using the smallest tip that provides the desired concentration factor for your application.

 

3 - Packaging Format by Target Application

All products are produced aseptically in a cleanroom environment. Understanding your downstream application will help identify which package format is best suited.

  • Non-irradiated CPTs -Bulk packaged and suitable for most applications due to the inherent low background.  Recommended if target organisms are non-ubiquitous or using selective assays.
  • Irradiated CPTs  - Individually wrapped and irradiated to provide added protection against bioburden. Best for culture-based downstream applications.

Tips are designed for use with the CP Select (CP Select™ sold separately) 

We recommend use with the CP sample carousel item #HC08042.

View Product

FluidPrep™ CPT - Unirradiated

Single-use, Unirradiated, Concentrating Pipette Tips (CPTs) are available in a variety of formats. Selecting the ideal CPT for use with the FluidPrep Concentrating Pipette System is crucial to achieving optimal performance - both in terms of speed and concentration factor of your target. 

 

Selecting the Right CPT - Factors to consider

1 - Pore Size based on Nature and Size of Target Particle

CPTs are available in four pore sizes – Ultra, 0.05 µm, 0.2 µm, and 0.45 µm to accommodate the wide range of target particle types and sizes. 

*Volume and flow rates will vary by matrix and selected menu settings

2 - Surface Area by Sample Matrix and Sample Volume

The complexity of your sample and overall volume to be processed will influence the speed and overall volume that can be processed effectively. Two options area available.

  • Standard CPTs Membrane surface area is 98 cm² nominal. Recommended for sample volumes over 200 mL and/or more complex or turbid matrices.
  • Mini 25 CPTs  - The membrane surface area is 25 cm² nominal and capable of smaller elution volumes with optimized menu settings. Recommended for sample volumes 200 mL or less and of low complexity/turbidity. Short-walled sample containers and the CP Sample Carousel are required for use.

As a general Rule of Thumb, we recommend using the smallest tip that provides the desired concentration factor for your application.

 

3 - Packaging Format by Target Application

All products are produced aseptically in a cleanroom environment. Understanding your downstream application will help identify which package format is best suited.

  • Non-irradiated CPTs -Bulk packaged and suitable for most applications due to the inherent low background.  Recommended if target organisms are non-ubiquitous or using selective assays.
  • Irradiated CPTs  - Individually wrapped and irradiated to provide added protection against bioburden. Best for culture-based downstream applications.

Tips are designed for use with the CP Select (sold separately) 

We recommend use with the CP sample carousel item #HC08042, and our selection of short-walled sample containers, Sample Cup Flip-Top 200ml item #HC08040-10, Sample Vial Flip-Top 10 mL item # HC08041-10, and Sample Cup with Conical Bottom item #AC08106-10.

 

 



View Product

FluidPrep™ Mini CPT - Irradiated

Single-use, Irradiated, Mini Concentrating Pipette Tips (CPTs) are available in a variety of formats. Selecting the ideal CPT for use with the FluidPrep Concentrating Pipette System is crucial to achieving optimal performance - both in terms of speed and concentration factor of your target. 

 

Selecting the Right CPT - Factors to consider

1 - Pore Size based on Nature and Size of Target Particle

CPTs are available in four pore sizes – Ultra, 0.05 µm, 0.2 µm, and 0.45 µm to accommodate the wide range of target particle types and sizes. 

*Volume and flow rates will vary by matrix and selected menu settings

2 - Surface Area by Sample Matrix and Sample Volume

The complexity of your sample and overall volume to be processed will influence the speed and overall volume that can be processed effectively. Two options are available.

  • Standard length CPTs - Membrane surface area is 98 cm² nominal. Recommended for sample volumes over 200 mL and/or more complex or turbid matrices.
  • Mini 25 CPTs  - The membrane surface area is 25 cm² nominal and capable of smaller elution volumes with optimized menu settings. Recommended for sample volumes 200 mL or less and of low complexity/turbidity. Short-walled sample containers and the CP Sample Carousel are required for use.

As a general Rule of Thumb, we recommend using the smallest tip that provides the desired concentration factor for your application.

3 - Packaging Format by Target Application

All products are produced aseptically in a cleanroom environment. Understanding your downstream application will help identify which package format is best suited.

  • Non-irradiated CPTs -Bulk packaged and suitable for most applications due to the inherent low background.  Recommended if target organisms are non-ubiquitous or using selective assays.
  • Irradiated CPTs  - Individually wrapped and irradiated to provide added protection against bioburden. Best for culture-based downstream applications.

Tips are designed for use with the CP Select (sold separately) 

We recommend use with the CP sample carousel item #HC08042, and our selection of short-walled sample containers, Sample Cup Flip-Top 200ml item #HC08040-10, Sample Vial Flip-Top 10 mL item # HC08041-10, and Sample Cup with Conical Bottom item #AC08106-10.

View Product

FluidPrep™ Mini CPT - Unirradiated

Single-use, Unirradiated, Mini Concentrating Pipette Tips (CPTs) are available in a variety of formats. Selecting the ideal CPT for use with the FluidPrep Concentrating Pipette System is crucial to achieving optimal performance - both in terms of speed and concentration factor of your target. 

 

Selecting the Right CPT - Factors to consider

1 - Pore Size based on Nature and Size of Target Particle

CPTs are available in four pore sizes – Ultra, 0.05 µm, 0.2 µm and 0.45 µm to accommodate the wide range of target particle types and sizes. 

*Volume and flow rates will vary by matrix and selected menu settings

2 - Surface Area by Sample Matrix and Sample Volume

The complexity of your sample and overall volume to be processed will influence the speed and overall volume that can be processed effectively. Two options are available.

  • Standard CPTs Membrane surface area is 98 cm² nominal. Recommended for sample volumes over 200 mL and/or more complex or turbid matrices.
  • Mini 25 CPTs  - The membrane surface area is 25 cm² nominal and capable of smaller elution volumes with optimized menu settings. Recommended for sample volumes 200 mL or less and of low complexity/turbidity. Short-walled sample containers and the CP Sample Carousel are required for use.

As a general Rule of Thumb, we recommend using the smallest tip that provides the desired concentration factor for your application.

 

3 - Packaging Format by Target Application

All products are produced aseptically in a cleanroom environment. Understanding your downstream application will help identify which package format is best suited.

  • Non-irradiated CPTs -Bulk packaged and suitable for most applications due to the inherent low background.  Recommended if target organisms are non-ubiquitous or using selective assays.
  • Irradiated CPTs  - Individually wrapped and irradiated to provide added protection against bioburden. Best for culture-based downstream applications.

Tips are designed for use with the CP Select (sold separately) 

We recommend use with the CP sample carousel item #HC08042, and our selection of short-walled sample containers, Sample Cup Flip-Top 200 mL item #HC08040-10, Sample Vial Flip-Top 10 mL item # HC08041-10, and Sample Cup with Conical Bottom item #AC08106-10.

View Product

FluidPrep™ Elution Buffer (CP Select™)

For use with CP Select™ only

 

Optimize the performance of your FluidPrep™ Concentrating Pipette System with our specially formulated Elution Buffers. Designed to enhance concentration efficiency through our patented Wet Foam Elution™ process, choosing the right elution buffer ensures optimal recovery, target integrity, and seamless compatibility with downstream applications. Use our guide to select the best elution buffer for your specific needs.

Note:
PBS, PBS-X and Tris Elution Fluids are irradiated and have min. of 90 days shelf-life at time of shipment. 
DMEM Elution Fluid is available in a 5-pack only, is non-irradiated. Store refrigerated.

pH levels:

Tris Elution Buffer – pH is typically between 5.75 – 7

PBS Elution Buffer - pH is typically between 5.4 - 6.65

Expert Support - If you need assistance in selecting the most suitable CPTs and elution buffer for your CP Select system, our team of experts is ready to help. Contact us for tailored advice and support to ensure optimal performance and results.

View Product

CP Select™ Daily System Care Kit

Formerly referred to as the Storage Fluid Maintenance Kit, the CP Select™ Daily System Care Kit includes routine system-care consumables used to support proper CP Select™ operation, shutdown, rinsing, storage, and decontamination when the instrument is in regular use.

This kit is required for the CP Select™ shutdown protocol and should be used according to the CP Select™ User Manual and Preventive Maintenance Schedule.

Kit includes:

  • 5 bottles of CP Select™ Storage Fluid
  • Maintenance Tip, item HC08005
  • Silicone Lubricant

Important distinction: For permeate collection workflows, or workflow-specific recommendations, follow the CP Select™ Permeate Pathway Cleaning guidance.

View Product

FluidPrep™ 1 µm Upstream Clarification Filter/Filter Bag

Fine upstream clarification for difficult, high-particulate liquid samples

The FluidPrep™ 1 µm Upstream Clarification Filter is a single-use fine prefiltration tool for reducing persistent suspended particulates before concentration. Use it when cloudy, clay-like, wastewater-impacted, environmental, or other difficult liquid samples contain fine solids that may interfere with CP Select™ or EasyElute™ workflows.

Because 1 µm filtration may retain cells, protozoa, fungi, organism fragments, biofilm-associated material, particle-associated eDNA/eRNA, or solids-associated targets, users should evaluate target recovery before routine use.

 

Some complex liquid samples contain fine suspended particles that remain after settling or coarse screening. These particles can contribute to slow flow, premature filter loading, or inconsistent concentration performance.

The FluidPrep™ 1 µm Upstream Clarification Filter supports the Clarify step of the InnovaPrep® 4C Workflow — Characterize → Condition → Clarify → Concentrate — by reducing fine particulate burden before concentration when a less aggressive approach is not sufficient.

 

Best used when samples contain:

  • Persistent fine suspended solids
  • Cloudy or clay-like turbidity
  • Fine mineral or sediment load
  • Wastewater-impacted water with difficult fine particulates
  • Environmental water, stormwater, canal water, lagoon water, or receiving water with persistent haze
  • Large-volume samples that remain difficult after coarse debris removal
  • Samples where direct CP Select™ or EasyElute™ concentration is limited by fine particulate burden

 

For gross debris, use coarse screening (e.g. 100 µm Mesh Upstream Clarification Filter). For CP Select™ workflows where fouling occurs during concentration, consider CPT-Attached Matrix Prefilters.

 

1EA = 1 Filter Bag

View Product

FluidPrep™ Sample Vial Flip-Top 10 mL

10 pack.

Holds 10 mL, polypropylene, bulk packed. 

Works well for small samples when using Mini CPTs on the CP Select™.

View Product

FluidPrep™ Sample Cup Flip-Top 200 mL

10 pack, 200 mL, flat bottom polypropylene container, bulk packed.

View Product

Sample Carousel for CP Select™

Adjustable sample stand for use with CP Select™. 

View Product

Fluidprep™ Hard Shell Rolling Travel Case

Rugged case with custom insert suitable for transport and field use. Accommodates instrument and consumables.

Instrument and consumables sold separately. 

View Product

Portable Power Station

The Portable Power Station is lightweight and can extend your sampling time in the field.

  • Up to 12 hours when paired with the FluidPrep™ CP Select™ 
  • Up to 10 hours for the AirPrep™ Cub or Bobcat Samplers
  • Solar panel option available

Includes AC

Compatible with the CP Select™ or AirPrep™ Samplers (Cub or Bobcat)

The images displayed on this website are for illustrative purposes only. The actual product you receive may vary in color, design, or other features due to ongoing product enhancements, manufacturing updates, or variations in display settings. Please contact us for more details.

Note:

  • Up to 2 weeks lead time
  • Available for North America Ground Shipment only

Inquire for delivery options to international destinations outside of the US


  • Portable Power Station | 600W 268W
  • 600W AC Pure Sine Wave Inverter (1,200W surge)
  • 268Wh Capacity
  • 430W Max. Fast Dual Charging
  • LiFePO4 Battery with 2,500+ Life Cycles to 80%
  • Recharge (AC/Car/Generator)
  • 9 Outputs for Charging Multiple Devices at once
  • Easy to Carry/ Fast Charging/ Safe & Reliable/ Cost-effective
View Product

BeFlat™ Degassing Jar for Carbonated Beverage Sample Prep

The BeFlat™ Degassing Jar is a patented, reusable sample-preparation tool designed to reduce dissolved gas in beer, soda, hard seltzer, cider, sparkling beverages, and other gasified liquids before concentration or downstream analysis.

Carbonated beverages can release CO₂ during sample handling, creating bubbles and foam that may slow or disrupt concentration. BeFlat™ helps prepare these samples for more reliable and efficient CP Select™ processing, supporting faster microbiology workflows that concentrate bacteria and other spoilage organisms from large sample volumes before culture-based or molecular testing.

When paired with CP Select™ Concentration Tips and Wet Foam Elution™, BeFlat™ enables a streamlined carbonated beverage workflow:

           Degas → Concentrate → Elute → Test

Benefits

Prepares carbonated beverages for CP Select™ concentration

Helps reduce bubbles, foam, and CO₂-related flow disruption

Supports beer-spoilage organism and beverage QC workflows

Useful before 0.45 µm or 0.2 µm CPT workflows

Reusable, autoclavable borosilicate glass jar

Supports culture-based or molecular downstream testing workflows

 

Streamlined Workflow

1 - Degas with BeFlat™
- Pour the carbonated beverage into the BeFlat™ Degassing Jar to release CO₂

2 - Concentrate with CP Select™
- Use the appropriate CPT Concentration Tip based on target and matrix behavior.

3 - Recover with Wet Foam Elution™
- Elute captured organisms into a small concentrate.

4 - Analyze
- Use the concentrate for culture, enrichment, qPCR/dPCR, sequencing, lateral flow, or other validated downstream methods.

 

Common Sample Types

Beer

Hard seltzer

Cider

Soda

Kombucha

Sparkling beverages

Carbonated water

Gasified product samples

Some in-process beverage samples

 

See Protocol for Degassing Beer and other Carbonated Beverages

View Product

CP Select Rinse Tip - 10 pack

Intended for Concentrating Pipette system maintenance when working with samples containing potentially corrosive substances.

View Product

BSL Aerosol Control Bundle for CP Select™

Contains:

  • 2 Liter Permeate Bottle
  • 5-pack of Vent Filters- to precent aerosol release from permeate liquid
  • Canister Puncture Tool - to enable pressure release in cans before autoclaving. 
View Product

FluidPrep™ Permeate Bottle with Vent Filter

Ensures no aerosol is released from the permeate liquid. 2L Bottle. For use with the Concentrating Pipette.

View Product

Permeate Vent Filters for CP Select™

 5-pack. Prevents aerosol release from the 2 L Permeate Bottle vent (sold separately).

0.2 µm disk filters.

View Product

FluidPrep™ Canister Puncture Tool

For use with CP Select™ and EasyElute™ elution buffer canisters.

To ensure both safety and compliance, we recommend that all cans be depressurized before autoclaving.

The canister puncture tool is designed specifically to safely depressurize and drain Elution Buffer canisters for disposal. When used properly, this tool mitigates the risk of pressure buildup and ensures safe processing during autoclaving. It can be screwed onto Nalgene-type bottles to catch any remaining fluid.

View Product

Permeate Line for CP Select™

Replacement permeate line with quick connect for the CP Select™

 

 

View Product

Tube Set for Storage Fluid Adapter

Tube-set that connects to the bung of the storage fluid bottle. Recommended to replace annually. The item is required for the daily shut-down maintenance procedure.

For use with CP Select™. This product contains the tube set only. Does NOT include Storage Fluid Adapter. 

View Product

Storage Fluid Adapter with Tube Set for CP Select™

Storage Fluid Adapter with Tubing Set for connecting storage fluid bottle and CP Select™. Replacement Item for CP Instruments. 

View Product

Maintenance Tip for CP Select™

Individual tip used for routine CP Select™ start-up and shut-down operations. 

This item is included in Storage Fluid maintenance kit.

Replacement item for CP instruments. 

View Product

Elution Port Cap for the CP Select™

Replacement cap for elution port on CP Select™.

Protects the fluid can interface port while the CP Select™ is not in use.

View Product

Tubing Clips for CP Wasteline

Package of three (3) tubing clips. 

View Product

AC Power Cord for CP Select™

Replacement Power Cord for the CP Select™. 

Power supply sold separately. 

View Product

Power Supply - CP Select™

Replacement power supply for the CP Select™ instruments.

Power cord sold separately. 

View Product

Accessory Kit for CP Select™

Kit contains single tube of silicone lubricant, alcohol wipes, tubing and maintenance tips, permeate line and storage fluid adapter.

View Product

FluidPrep™ EasyElute™ - Large Volume Concentration Kit

The Fluidprep™ EasyElute™ Large Volume Concentration Kit is your solution for efficient sample concentration and immediate recovery from large sample volumes. It is designed to streamline your workflow and enhance assay sensitivity in detecting trace microorganisms and particles from fluid volumes of 5, 10, 100+ L. The one-pass method uses robust filtration followed by instant sample recovery using InnovaPrep's patented Wet Foam Elution process delivering a highly concentrated sample that improves sensitivity for detection by any analysis method - including culture, PCR, and sequencing - with unprecedented speed and efficiency.

Whether you're trying to detect viruses, bacteria, parasites, or other biological or synthetic targets, EasyElute™ offers unparalleled ease-of-use and performance.

Kit Includes: 30 kD ultrafilter, elution buffer, with autoclavable tubing and connectors.

Requires a pump for operation. For pump recommendations and Specifications, visit our website:  EasyElute™ Large Volume Concentration Kit Specifications and Pump Reco – InnovaPrep

Options Available

  • Elution Buffer (PBS or Tris) - irradiated
  • Single kit or 10 pack
  • Tubing Set - Standard (untreated) or Autoclaved
View Product

FluidPrep™ EasyElute™ Resupply Kit

EasyElute™ Resupply Kit – A Cost-Effective and Eco-Friendly Solution


Reuse your tubing, reduce waste, and save costs with the EasyElute™ Resupply Kit. Designed for simplicity and sustainability, this kit lets you leverage the reusable tubing and fittings from your EasyElute™ Large Volume Concentration Kit. Tubing can be autoclaved prior to reuse if desired.

 

Includes: Single-use EasyElute™ Elution Buffer canister (1) and EasyElute™ Filter (1)

 

Choose the EasyElute™ Resupply Kit for an economical and green approach to superior sample preparation. Use the guide below to select the ideal buffer for your needs and elevate your results while reducing waste.

Note: Elution Buffer is irradiated and has a min of 90 days shelf-life at time of shipment. 

 

Please choose PBS or Tris buffer.

Tubing and connectors not included.

View Product

FluidPrep™ EasyElute™ Canister Adapter

Adapter to allow elution of filter module with FluidPrep™ Easy Elute™ Elution Buffer Canister. 

This product is NOT to be used with CP Select™.

View Product

FluidPrep™ EasyElute™ Elution Buffer

Enhanced Particle Recovery and Concentration from Large Sample Volumes

 

The EasyElute™ Elution Buffer is a critical component of the EasyElute™ Large Volume Concentration Kit, enabling InnovaPrep's proprietary Wet Foam Elution™ process for highly efficient particle recovery. These single-use canisters are essential for achieving maximum recovery, preserving target integrity, and ensuring compatibility with downstream applications.

 

Our proprietary Wet Foam Elution process optimizes recovery and concentration efficiency, making these buffers ideal for seamless compatibility with downstream applications. Use our selection guide to choose the right buffer for your specific needs and elevate your results with the EasyElute™ System.

Note: Elution Buffer is irradiated and has a min of 90 days shelf-life at time of shipment. 

 

Do not use with CP Select™, may cause damage.

 

The FluidPrep™ EasyElute™ Canister Adapter (CC08102) is required for use and sold separately. 

View Product

FluidPrep™ 100 µm Mesh Upstream Clarification Filter | Tie-on Filter Bag

Coarse upstream debris management for FluidPrep™ concentration workflows

The FluidPrep™ 100 µm Mesh Upstream Clarification Filter is a simple, single-use prefiltration tool for reducing gross debris before concentration. It helps make large-volume, debris-containing, or wastewater-impacted liquid samples more processable before CP Select™ or EasyElute™ workflows.

Use it when fibers, vegetation, grit, algae, large particulates, produce debris, or other coarse material may interfere with downstream concentration.

Main product description

Complex liquid samples often contain large debris that can slow processing, clog downstream components, or make concentration less reliable. The FluidPrep™ 100 µm Mesh Upstream Clarification Filter provides a practical first clarification step before FluidPrep™ concentration workflows.

 

As part of the InnovaPrep® 4C Workflow

 Characterize → Condition → Clarify → Concentrate

The 100 µm Mesh Upstream Clarification Filter supports the Clarify step by removing coarse debris only when needed.

The goal is not maximum solids removal. The goal is target-aware matrix management: reduce gross debris and improve processability while preserving the biological fraction needed for downstream analysis.

 

Best used for

  • Wastewater and wastewater-impacted waters with visible debris
  • Environmental water, stormwater, canal water, and surface water samples
  • Produce rinse or wash water with pulp, fibers, soil, or plant material
  • Aquaculture, pond, lagoon, or recirculating water samples
  • Large-volume water samples containing grit, algae, vegetation, or sediment
  • Workflows where coarse debris should be removed before CP Select™ or EasyElute™ concentration

Common applications

Wastewater surveillance
Helps manage gross debris before concentration of wastewater or wastewater-impacted samples.

Environmental water monitoring
Useful for surface water, stormwater, canal water, lagoon water, and other samples containing large debris or algae.

Produce rinse and wash water
Supports removal of coarse plant material, fibers, soil clumps, or debris before concentration.

Large-volume concentration workflows
Supports processability when large-volume samples contain visible particulates that may interfere with downstream concentration.

View Product

FluidPrep™ CPT Matrix Prefilter

The FluidPrep™ CPT Matrix Prefilter allows simultaneous prefiltration and concentration of target pathogens in difficult, highly turbid samples. 

  • For Use with the CP Select™ CPTs
  • Eliminates the need for centrifugation or manual filtration
  • For use with difficult sample types (wastewater, turbid environmental samples, homogenized foods, etc.)
  • Pre-filters while sampling removing large non-target particles and inhibitors
  • High-flow

Available with various pore size options: (Sold as 10 packs and 50 packs) 

  • 1 Micron pore size, unirradiated. Use these prefilters with 0.05µm or Ultra CPTs
  • 25µm pore size, unirradiated. Use these prefilters with 0.2µm or 0.45µm CPTs
  • 8µm pore size, unirradiated. Use these prefilters with 0.05µm or Ultra CPTs

*Concentrating Pipette Tips (CPTs) and CP Select™ sold separately. 

View Product